Skip Ribbon Commands
Skip to main content

Boiler, buffer tank, mixed circuit, DHW, solar circuits (Hy0404p)

Boiler, buffer tank, mixed circuit, DHW, solar circuits (Hy0404p)
  • Outdoor temperature-compensated control with buffer tank for one radiator, convectors or low temperature heating circuit. Integrated differential temperature control for controlling a solar system. Burner control for demand-based control of all boiler types. Various variants of hot water priority circuit.
  • Note: System no. 404 means that certain parameters must be set for this application to function.

Mixed heating1 circuit
Domestic Hot Water1 pump
Boiler1,2 stages
Solarfor DHW, heating
Buffercharge control

Functions
  • The basic functions are contained in an indestructible program.
  • All the parameters are predefined with sensible basic settings and allow individual adjustments as necessary. PCs are not required for this.
  • All the relay outputs can be tested manually.
Boiler control
  • Sliding boiler temperature control for one-stage boiler
Heating circuit
  • Time switch for daily, weekly and holiday programs for heating circuit
  • Optimisation of switch-on times
  • Caretaker function, frost protection function
  • Outdoor temperature-compensated heating circuit, with room tie-in as necessary
  • Min./max. limiting of flow temperature
  • Cooling function - switchover based on outside temperature
Hot water control
  • Time switch with daily and weekly program for hot water filling pump
  • Anti-legionella automatic system
  • Hot water priority circuit
  • Outdoor temperature-compensated parallel operation only in mixed circuit
Solar control
  • The temperatures of the collector (KVLF) and the hot water tank (VE2) are compared. The control unit switches the solar pump on when the collector sensor detects a higher temperature than the tank sensor.
  • Solar energy is used to fill the hot water tank and the buffer tank.
Combination
  • Combination option of up to five freely-selectable SMILE controllers
Communication
  • Communication takes place over the system bus without additional interfaces
  • Distance (max. 100 m)
  • All the data required for the control system is communicated
  • Remote operation with the wall modules SDW.. also takes place using the system bus
Fault message
  • If the required temperatures cannot be achieved within a reasonable time, or sensors interrupt or short-out, then the controller will generate a fault message.

Related Parts

Product Type Description
Application for Smile digital controller
_Hy0404p
_Hy0404p
Microprocessor controller for heating circuit, boiler and hot water control
SDC9-21WM
SDC9-21WM
With connection base for wall installation
SDC9-21PM
SDC9-21PM
With connectable terminal strips for control panel installation
Sensors
AF20-B65
AF20-B65
Outside air temperature sensor
VF20-3B54NW
VF20-3B54NW
Buffer, strategy sensor KSPF, VE1 (2)
SF20-B54
SF20-B54
Contact temperature sensor VF
KTF20-65-2M
KTF20-65-2M
Boiler, hot water temperature sensor (without well) WF, SF, VE2 (3)
Recommended
SDW10WE
SDW10WE
Remote control with temperature selector/sensor and mode switch
Selectable
VF20-1B54NW
VF20-1B54NW
Immersion temperature sensor (instead of SF20-B54)
VF20-3B54NW
VF20-3B54NW
Hot water sensor with optional NIRO immersion well (instead of KTF20-65-2M)
SDW30
SDW30
Easy-to-use remote operation with display and complete programming unit along with temperature sensor/selector (instead of SDW10)
SCS-12
SCS-12
Base for Smile Controller, for control panel installation as touch protection
SWS-12
SWS-12
Connecting base for wall installation of SMILE panel models
SRR
SRR
Reducing attachment frame for control panel installation, assuming available control panel cut-out on controllers ZG52 /53 /55 / 82 /85 or ZG215 /215V /252 /254