Descrizione del prodotto
Safety groups of this type are used to protect pressurised
water heaters according to the requirements of DIN 4753-1,
EN 806-2 and DIN EN1488.
They are compact appliances which incorporate all the
necessary safety devices such as check valve, shut-off valve, test point, diaphragm type safety valve and pressure
reducing valve in one unit.
The safety valve protects the downstream cylinder, pressure
vessel etc. by automatically opening when excess pressure
occurs. The check valve prevents back pressure, backflow
and back syphonage of water from the hot water unit.
In addition, a balanced seat pressure reducing valve is fitted on the inlet to control the supply pressure to that required for the system.
Proprietà tecniche
Approvazioni |
|
Fluido |
Acqua Potabile |
Dim. DN |
20 mm |
Impostazione pressione |
6 bar |
Tipo di attacchi |
filettatura esterna |
Diametro degli attacchi |
3/4 inch |
Campo del setpoint di pressione |
1,5 ... 6 bar |
Massima temperatura del fluido |
40 oC |
Materiale del corpo |
ottone resistente alla dezincatura |
Materiale copri molla |
materiale sintetico |
Camera filtro trasparente |
Sì |
Scala Setpoint |
Sì |
Sede bilanciata |
Sì |
Informazioni supplementari |
- Testato in accordo a DIN EN 1488
- Approvato per basse emissioni sonore Classe 1
- Risponde alle regolamentazioni UBA per l'acqua potabile
- Pressure reducing valve with inlet pressure balancing - inlet pressure fluctuation does not influence the outlet pressure
- Gli inserti di sostituzione rendono la manutenzione semplice
- Drenaggio facilitato
- Connessione di scarico standardizzata
|
Posizione di montaggio |
orizzontale o verticale |
Massima pressione in ingresso |
16 bar |
Minimum pressure drop |