Skip Ribbon Commands
Skip to main content
​This extension for Google Chrome will allow you to click on the links in the PDF CAD files and open the related documents from your browser.

Thermostatic mixing valve with scald protection, TM200

Thermostatic mixing valve with scald protection, TM200

TM200 thermostatic mixing valves provide control of the water temperature and are used: For centralized control on hot water supply units or for localized control adjacent to...

Product Description

TM200 thermostatic mixing valves provide control of the water temperature and are used: For centralized control on hot water supply units or for localized control adjacent to point-use outlets;  In heating systems with underfloor heating or for limiting boiler return temperatures. Where a system includes a hot water circulation circuit, a return flow retarder unit (see accessories) must be fitted to prevent cold water back-feeding and cooling the mixed water at the outlets.

Technical Properties

Media

Drinking water

Max. media temperature 90 oC
Temp. setpoint range 30 ... 60 oC
Body material brass, dezincification resistant
Additional Descriptions
  • Highly sensitive thermal element with good all-round water temperature sensing, even at low flow rates
  • Simple setting of the required water temperature
  • Scald protection - the hot water inlet is automatically cut off if the cold supply fails provided that the hot water inlet temperature is at least 10 K higher than that of mixed water setting
  • The cold water inlet is automatically cut off if the hot supply fails
  • Inner components are of scale-resistant materials
  • Options with integrated check valves for cold and hot water inlet available
  • Meets UBA regulations for drinking water
Mounting position horizontal or vertical
Maximum operating pressure 10 bar
Temperature control accuracy 4 K

Products

Product Type Port connection
With threaded male connections 3/4 inch

TM200-3/4A
external threads
With 22 mm soldered connections

TM200-3/4B
soldering

Accessories and replacement parts

Accessories

Image Description Product Type Downloads
Return flow-retarder unit for fitting to systems which include a hot water circulation circuit - to prevent cold water backfeeding and cooling the mixed water at the outlets Operating pressure max. 10 bar; Operating temperature max. 90C; Installation orientation: Arrow pointing in flow direction KB191-3/4  

Spare Parts

Image Description Product Type Downloads
Regulation valve complete TM200A-30/60