Product Description
The refilling combination serves filling and refilling of closed heating systems according to DIN EN 12828:2014-07. It can be connected in accordance with EN 1717:2000 permanently with the drinking water supply. The refilling combination combines a BA type backflow preventer, pressure reducing valve and two ball valves in one appliance. The unit consists of all needed devices for refilling a heating installation according to conforming standards are contained.
Technical Properties
Approvals |
DVGW |
Media |
Drinking water |
Port connection |
external threads |
Mounting position |
horizontal |
Outlet pressure |
1,5 ... 4 bar |
Max. media temperature |
65 oC |
Materials |
Dezincification resistant brass housing, complete backflow preventer with discharge connection, valve cartridge and valve insert in high-grade synthetic material, fibre-reinforced EPDM diaphragm, NBR and EPDM seals, spring steel adjustment spring, stainless steel fine filter mesh. |
Filter mesh |
200 micron |
Liquid category (EN1717) |
class 4 |
Inlet pressure range |
2 ... 10 bar |
Preset Outlet Pressure |
1,5 bar |
Additional description |
- Permanent connection with the drinking water supply in accordance with EN 1717 by hose line or piping is possible
- Optimal protection of the drinking water supply system
- Pressure reducing valve with inlet pressure balancing - inlet pressure fluctuation does not influence the outlet pressure
- Outlet pressure adjustable and directly visible on the pressure gauge
- Low maintenance effort - cartridge insert and valve insert are completely replaceable
- Meets KTW/ W270 regulations for drinking water
|