Product Description
Thermostatic mixing valves of this type are used for central regulation of the water temperature in solar-powered, bivalent water heaters.
A cold water break can be fitted in the circulation line in water heater systems, which prevents cold water from mixing at the extraction point via the circulation line.
Technical Properties
Media |
Water |
Port connection |
external threads |
Max. media temperature |
110 oC |
Temp. setpoint range |
30 ... 60 oC |
Body material |
brass, dezincification resistant |
Body finishing |
nickel plated |
Additional Descriptions |
- Highly sensitive thermal element with good all-round water-temperature sensing, even at low flow rates
- Simple setting of the required water temperature
- Scald protection - the hot water inlet is automatically cut off if the cold supply fails provided that the hot water inlet tempe-rature is at least 10 K higher than that of mixed water setting
- The cold water inlet is automatically cut off if the hot supply fails
- Meets KTW recommendations for potable water
- Inner components are of scale-resistant materials
|