Skip Ribbon Commands
Skip to main content

Heating, District Heating and Multi-Fuel OTC Controller, SMILE

Heating, District Heating and Multi-Fuel OTC Controller, SMILE

Microprocessor controller with fixed hard- and software. Configuration with 15 sets of parameters. Remote access with App and Gateway...

Product Description

Microprocessor controller with fixed hard- and software. Configuration with 15 sets of parameters. Remote access with App and Gateway.

For all Heating and District Heating applications with:

  • direct heating circuit and/or mixed heating circuit(s)
  • boiler burner
  • domestic hot water
  • heat exchanger valve

Technical Properties

Control software the software application can be selected, by keying in a planttype code, and can be adjusted with parameters; or use no code number and configure the application with the parametersets only
Modes of operation heating without time program, eco, summer, manu, auto
Time program heating with own week clock, DHW with own week clock, 15 vacation periods
Hardware outputs

all outputs are relay outputs with a maximum contact load of 2A 250V

  • the standard relay outputs are for pumps and valves, and are controlled from the selected application; mixing valves need 2 output relays
  • the function for the additional relay outputs can be set with parameters
Applicable sensor types NTC 20 kohm
Bus system description
  • Honeywell Home bus sytem for max. 5 SMILE controllers, and 3 setpoint units per controller; max. buslength 100 m; the controller can also be used as stand-alone controller.
  • OpenTherm for all models, except SDC3-40..
Protection class IP30
Max. ambient temperature 50 oC
ErP Class VI
Power supply 230 Vac | 5.8 VA
Batteries included 3VLi
Additional Descriptions One of the hardware inputs is for a pulse contact. This can be used for example for counting running hours. With parametersettings the amount of counted pulses can be used for switching pumps or boilers.

Certifications and Awards

Related Material

Продукти

Product Type Burner output
Heating circuit
Domestic Hot Water
Additional output
Hardware inputs
Panel mounting, HxWxD = 96x144x75 mm; Display languages and documentation: German, French, English, Dutch; 11 other display languages also supported

SDC3-10PM
1 stage pump loading pump 4 (1 var.)

SDC3-40PM
1x: mixing valve + pump 4 (1 var.)

SDC7-21PM
1/2 stages 1x: mixing valve + pump; pump loading pump 6 (SDC 1v DHC 3v)

SDC9-21PM
1/2 stages 1x: mixing valve + pump; pump loading pump 2 variable 11 (3 var.)

SDC12-31PM
1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.)
Wall mounting, HxWxD = 96x285x90 mm; Display languages and documentation: German, French, English, Dutch; 11 other display languages also supported

SDC3-10WM
1 stage pump loading pump 4 (1 var.)

SDC3-40WM
1x: mixing valve + pump 4 (1 var.)

SDC7-21WM
1/2 stages 1x: mixing valve + pump; pump loading pump 6 (SDC 1v DHC 3v)

SDC9-21WM
1/2 stages 1x: mixing valve + pump; pump loading pump 2 variable

11 (3 var.)


SDC12-31WM
1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.)
Panel mounting, HxWxD = 96x144x75 mm; Display languages and documentation: Romanian, Russian, Polish, Hungarian, Czech, Turkish, English

SDC3-10N
1 stage pump loading pump 4 (1 var.)

SDC3-40N
1x: mixing valve + pump 4 (1 var.)

SDC7-21N
1/2 stages 1x: mixing valve + pump; pump loading pump 6 (SDC 1v DHC 3v)

SDC9-21N
1/2 stages 1x: mixing valve + pump; pump loading pump 2 variable 11 (3 var.)

SDC12-31N
1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.)
Panel mounting, HxWxD = 96x144x75 mm; Display languages and documentation: Italian, Spanish, Swedish, Norwegian; 11 other display languages also supported

SDC3-10PMN
1 stage pump loading pump 4 (1 var.)

SDC3-40PMN
1x: mixing valve + pump 4 (1 var.)

SDC7-21PMN
1/2 stages 1x: mixing valve + pump; pump loading pump 6 (SDC 1v DHC 3v)

SDC12-31PMN
1/2 stages 2x: mixing valve + pump; pump loading pump 2 variable 12 (3 var.)

Accessories and replacement parts

Sensors

Image Description Product Type Downloads
Outdoor temperature sensor NTC AF20-B65  
Water temperature sensor, NTC, strap on pipe SF20-B54  
Water temperature sensor, NTC, with optional well (135 mm) VF20-1B54NW  
Water temperature sensor, NTC, with optional well (300 mm) VF20-3B54NW  
Water temperature sensor NTC, cable type KTF20-65-2M  
Room temperature sensor NTC RF20  
Water temperature sensor for solar panel VFF00-220P65  

Remote setpoint selector with temperature sensor, night, day and auto switch

Image Description Product Type Downloads
Setpoint unit Western Europe SDW10WE  
Setpoint unit Eastern Europe SDW10EE  

Comfortable digital remote setpoint selector with display, temperature sensor, access to the controller functions

Image Description Product Type Downloads
Digital setpoint unit Western Europe SDW30  
Digital setpoint unit Eastern Europe SDW30N  

Tamper proof covers for setpoint units

Image Description Product Type Downloads
Cover for SDW10.. TG510A  
Cover for SDW30.. TG511A  

Mounting accessories for panel models

Image Description Product Type Downloads
Connecting base for wall installation SWS-12  
Base for touch protection SCS-12  
Reducing frame for panel cut-out on controllers ZG52 /53 /55 / 82 /85 or ZG215 /215V /252 /254 SRR  
Terminal block set for Smile controller (N-version), 10 sets TBS-SMILE  
Single Terminal block set for Smile controller (N-Version) TBS-smile-1kit  

Accessories for models with boiler burner output

Image Description Product Type Downloads
Cable accessory AKA3  

Smile Connect

Image Description Product Type Downloads
Gateway for remote access with App SCN-10  
Installation kit for installers, for initial set up SCI-10  
WiFi stick for SCN-10 SCW-10  

Room Connect; ErP Class VIII

Image Description Product Type Downloads
For communication between Smile and HCE80, HR92, HCF82, T87RF. Integrated WiFi. Supplied with network cable. SRC-10