Skip Ribbon Commands
Skip to main content
​This extension for Google Chrome will allow you to click on the links in the PDF CAD files and open the related documents from your browser.

Universal controller for mixing circuit

Universal controller for mixing circuit

Wireless universal mixing valve controller for heating or cooling zone control. The controller receives heat demand signals (RF 868,3 MHz)from ther...

Product Description

Wireless universal mixing valve controller for heating or cooling zone control. The controller receives heat demand signals (RF 868,3 MHz)from thermostats CM67RFMV or CM67z.
The CM67RFMV also provides parameter settings for: minimum water temperature setpoint, mixing valve runtime, pump after running ime and heating or cooling operation mode.

Technical Properties

Control functions room temperature control; water temperature control (optional)
Manual operation functions push buttons for valve open/close
ErP Class V
Control output signal
  • 2x 230 V (3 A) on relay contacts for mixing valve open/close (not potential free contacts!)
  • 230 V (3 A) on relay contact for pump on/off (not a potential free contact!)
RF communication distance 30 m
Blocking immunity Receiver class 2 (ETSI EN300220-1 version 1.3.1)
LED functions mixing valve open/close: red/green; pump on: green; and several error messages: red
Housing (HxWxD) 161.5 mm | 121 mm | 46 mm
Mounting DIN-rail or wall
Protection class IP54
Power supply 230 V;50Hz | max. 1380 VA

Products

Product Type Product description
Controller

HM80
Universal mixing valve controller
Packages

HMC80
1x CM67RFMV, 1x HM80, 4x Eurofix cable glands

HMC82
1x CM67RFMV, 1x HM80, 4x Eurofix cable glands, 1x T7414C1012

Accessories and replacement parts

Additional products for HM80

Image Description Product Type Downloads
Chronotherm room thermostat CM67RFMV  
Water temperature sensor, NTC, strap on pipe SF20-B54