Skip Ribbon Commands
Skip to main content
    

Air conditioning, Cooling & Refrigeration

Honeywell has always the perfect choice for all transportation and bus  A/C applications.
When it comes down to service, comfort, performance, environment and safety, more and more manufacturers are choosing Honeywell for their products. The success of their products proves that they have made the right choice. After all, what could be better than installing all the Honeywell know-how into your products?

Whether in refrigeration or mobile air
conditioning systems for bus and train,
we can count many of our customers as
true market leaders.
Extreme conditions require very robust
valves and maximum experience.Low leakage features and rapid, easy installation for us and our customers are
the key to sustainable success.

From 2015, the use of fluorinated greenhouse gases will be regulated under the new EU regulation 517/2014 in order to assist the protection of the climate and the environment even further. This will have a direct impact on refrigeration, air-conditioning and heat pump systems.

 

Benefits

Application & Products

pressure equalisation
charge
warm thermal head
superheat setting
connections
Port
construction
benefits
TOEX
Thermostatic Expansion Valve
with fixed orifice 0,5 - 4,5
TOEX
Thermostatic Expansion Valve
with fixed orifice 0,5 - 4,5
TLEX
Thermostatic Expansion Valve
with fixed orifice 0,5-4,5
TLEX
Thermostatic Expansion Valve
with fixed orifice 4,75 - 7
TMV(X)BL
Thermostatic Expansion Valve
with interchangeable orifice 0,3 - 4,75
TMX
Thermostatic Expansion Valve
with interchangeable orifice 4,5 - 11
ESDR
Electronic Suction Pressure Regulation Valve
external external external external external external, in the valve body
combi adsorber charge or MOP charge combi adsorber charge or MOP charge combi adsorber charge for several refrigerants, MOP charge MOP charge combi adsorber charge for serveral refrigerants MOP - or liquid charge
adjustable superheat setting at two-way construction adjustable superheat setting adjustable superheat setting adjustable superheating setting adjustable superheating setting
o-ring connections o-ring connections solder connections solder connections inlet flare connection, outlet solder connection
Balanced Port Balanced Port
two-way construction angle construction
  • o-ring connection for fast installation and service
  • stable control behaviour
  • small capacity steps orifice to orifice for proper capacity selection for Bus A/C and Transport Cooling
  • o-ring connection for fast installation and service
  • stable control behaviour, small capacity steps orifice to orifice for proper capacity selection for Bus A/C and Transport Cooling
  • with stable adsorber and MOP-charges with ballast for Transport Cooling
  • small capacity steps orifice to orifice for proper capacity selection for Transport Cooling needs
  • warm thermal head to avoid charge migration in case of MOP-charges
  • on request with bypass to equalize high and low pressure during stand still time
  • balanced Port
  • with stable MOP-charges with ballast for Bus A/C and Transport Cooling
  • warm thermal head to avoid charge migration in case of MOP-charges
  • bi-flow function possible
  • stable and safe adsorber charge
  • changeable orifice for flexible cooling capacity adaption
  • small capacity steps orifice to orifice for proper capacity selection for Bus A/C and Transport Cooling
  • easy handling of the solder adapter
  • flexible valve design
  • Balance-Port, warm thermal head
  • MOP-charges with ballast for BUS A/C and Transport Cooling
  • small capacity steps orifice to orifice for proper capacity selection for Bus A/C and Transport Cooling
  • proportional valve characteristics
  • low pressure drop on fully open valve