Heating system with a buffer tank (Hy0406)

Heating system with a buffer tank (Hy0406)

The buffer tank is loaded by an external heat source (solid fuel boiler etc.). The controller controls a mixing loop for radiators, convectors or low temperature heating circuits. A constant temperature control is also possible. Domestic hot water control and the control of the circulation pump are also handled by the controller.

  • Note: System no 406 means that certain parameters must be set for this application to function

Mixed heating1 circuit
Domestic Hot Water2 pumps
Buffercharge control

  • Functions
  • The basic functions are contained in an indestructible program.
  • All the parameters are predefined with sensible basic settings and allow individual adjustments as necessary. PCs are not required for this.
  • All the relay outputs can be tested manually.
  • Heating circuit
  • Time switch for daily, weekly and holiday programs for each heating circuit
  • Optimisation of switch-on times
  • Caretaker function, frost protection function
  • Outdoor temperature-compensated mixed circuit/direct heating circuit, as required with room temperature compensation
  • Hot water control
  • Time switch for daily, weekly and holiday program
  • Anti-legionella automatic system
  • Hot water priority circuit or parallel operation with heating supply
  • Circulation pump control with different control strategies
  • Combination
  • Combination option of up to five freely-selectable SMILE controllers
  • Communication
  • Communication takes place over the system bus without additional interfaces
  • Distance (max. 100 m)
  • All the data required for the control system is communicated
  • Remote operation with the wall modules SDW.. also takes place using the system bus
  • Fault message
  • If the required temperatures cannot be achieved within a reasonable time, or sensors interrupt or short-out, then the controller will generate a fault message.

Related Parts

Product Type Description
Application for Smile digital controller
_Hy0406
_Hy0406
Microprocessor controller for heating circuit, boiler and hot water control
SDC9-21WM
SDC9-21WM
With connection base for wall installation
SDC7-21WM
SDC7-21WM
With connection base for wall installation
SDC7-21PM
SDC7-21PM
With connectable terminal strips for control panel installation
SDC9-21PM
SDC9-21PM
With connectable terminal strips for control panel installation
Sensors
AF20-B65
AF20-B65
Outside air temperature sensor
SF20-B54
SF20-B54
Contact temperature sensor VF
KTF20-65-2M
KTF20-65-2M
Buffer temperature sensor VE
Recommended
SDW10WE
SDW10WE
Remote control with temperature selector/sensor and mode switch
Selectable
VF20-1B54NW
VF20-1B54NW
Immersion temperature sensor (instead of SF20-B54)
VF20-3B54NW
VF20-3B54NW
Hot water sensor with optional NIRO immersion well (instead of KTF20-65-2M)
SDW30
SDW30
Easy-to-use remote operation with display and complete programming unit along with temperature sensor/selector (instead of SDW10)
SCS-12
SCS-12
Base for Smile Controller, for control panel installation as touch protection
SWS-12
SWS-12
Connecting base for wall installation of SMILE panel models
SRR
SRR
Reducing attachment frame for control panel installation, assuming available control panel cut-out on controllers ZG52 /53 /55 / 82 /85 or ZG215 /215V /252 /254